Taufique T Ansari , Mahesh H Gupta, Ritesh D Maurya, Rugved V Patil ,Mrs. Archana Gaikwad
DOI : 10.46335/IJIES.2023.8.4.8
Abstract –Autoclave is known as Steam Sterilizers. The size of autoclave can vary depending on the capacity required and the application. The recommended temperatures for sterilization range between 121°C to 135°C, with the minimum exposure time required to kill microorganisms being determined by the manufacturer. In this paper, the main focus is to create a system in which the waste of material do not take place. By using the spiral binding process over the autoclave to reduce the adhesiveness of the material over the inside wall of the autoclave. It also include research methodology which shows the gap between the previous research and this research. Testing parameters such as design pressure, temperature, working pressure, temperature, and hydraulic test pressure are crucial before using an autoclave in an industrial setting. This paper involve 3-D Designing of Autoclave which was execute in Autodesk Fusion 360.
Innovative Scientific Publication,
Nagpur, 440036, India
Email:
ijiesjournal@gmail.com
journalijies@gmail.com
© Copyright 2025 IJIES
Developed By WOW Net Technology